2-9. poe auto checking – LevelOne GEP-0950 User Manual

Page 59

Advertising
background image

4-2-9. PoE Auto Checking

Function name:

PoE Auto Checking

Function description:

The function is using for PD auto checking. It can allow user to control the PoE
function by using the ping command, in order to turn on or off any PD which
connect with port assign.

Parameter description:

Port No:

Port number.

Ping IP Address:

To set up the PD’s IP address which you need to check it is alive..

Interval Time:

To set up the spacing interval time to do ping check, the default value is
30 seconds. The available range is 10 to 120 seconds.

Retry Time:

To set up the number of times for switch to check PD is alive.

Failure Log:

To display the PD’s Ping result and log. The error means switch to ping
the PD is failure or total means total switch to do ping frequency.

Failure Action:

To set up when PD is failure and switch action command. The values are
“Nothing” and “Reboot Remote PD”.

PD Class:

The switch ping check PD failure “P.O.E” restarts the buffer time of switch.
The default is 15 seconds. The available range is 3 to 255 seconds