Entrapment protection devices, Additional features – LiftMaster RSW12V Residential / Light Commercial Swing Gate Operator with Battery Backup User Manual

Page 27

Advertising
background image

26

ADDITIONAL FEATURES

» ENTRAPMENT PROTECTION DEVICES

To prevent SERIOUS INJURY or DEATH from a moving gate:
• Entrapment protection devices MUST be installed to protect anyone who may

come near a moving gate.

• Locate entrapment protection devices to protect in BOTH the open and close gate

cycles.

• Locate entrapment protection devices to protect between moving gate and RIGID

objects, such as posts or walls.

CONTACT SENSORS (EDGE SENSOR)
Edge sensor models G65MG0204, G65MG0205, G65MGR205 or G65MGS205
(2-wire, non-monitored).

Connect the contact sensor wires to either the CLOSE EDGE or
OPEN EDGE/PHOTO terminal on the control board.

• CLOSE EDGE: Will detect an obstruction while the gate is closing.
• OPEN EDGE/PHOTO: Will detect an obstruction while the gate is opening.
If the electrically activated edge sensor comes in contact with an obstruction while the
gate is closing/opening, the gate will stop and reverse direction for a short time. The
gate will remain in this position until another command is given. If the edge sensor
comes in contact with the obstruction a second time, the gate will stop and reverse
direction for a short time and the operator alarm will sound. The alarm will sound
(up to 5 minutes) and the operator will have to be reset before it will resume normal
operation.

1

NON-CONTACT SENSORS (12 VDC PHOTOELECTRIC SENSORS)
Photoelectric sensor model 50-220.

Connect the non-contact sensor wires to either the OPEN PHOTO or CLOSE
PHOTO terminal on the control board.

It is best to use failsafe photoelectric sensors. If a photoelectric sensor is not working
or loses power or the photo beam is permanently blocked, the photoelectric sensor
will stop ALL gate operation.
• CLOSE PHOTO: If the photoelectric sensor beam is broken while the gate is closing,

the gate will stop and reverse to the fully open position. The obstruction must be
cleared before the operator will resume normal operation.

• OPEN PHOTO: If the photoelectric sensor beam is broken while the gate is opening,

the gate will stop and stay in that position until the obstruction is cleared. Once the
obstruction is cleared the operator will resume normal operation.

NOTE: The OPEN EDGE/PHOTO terminal may be used as a secondary input for
photoelectric sensors (as in dual gate applications, when more than one OPEN PHOTO
is needed).
Property

owners are obligated to test photoelectric sensors monthly.

1

Entrapment

Danger

Entrapment

Danger

CLOSE
EDGE

OPEN EDGE/

PHOTO

OPEN EDGE/

PHOTO

OPEN
PHOTO

CLOSE
PHOTO

Safety Danger

UL Listed Edge Sensor

3 Edge Contact Sensor

1

1

Safety Non-Contact Sensor

Entrapment Non-Contact Sensor

TO REMOVE CHAMBERLAIN PHOTOELECTRIC SENSORS

Remove the photoelectric sensor wires from the terminal block.

Press the LEARN LIMITS button.

Press the reset button.

1

2

3

Advertising