7.1.5 IRecOptions::SetPostTriggerPercentage


HRESULT SetPostTriggerPercentage (

[in] short posttrigger_percentage );


Sets the post-trigger buffer size.


Parameters

posttrigger_percentage

Size of post trigger buffer in percents of the
whole recording buffer ( see 7.1.4 )

Return values

E_INVALIDARG

Invalid percentage was specified.

Remarks


This method call has no effect if recording mode was set to

RMODE_SNAPSHOT

.

The default setting is 50%.

Example


WSH:

CurrentDir = Left(WScript.ScriptFullName, InstrRev(WScript.ScriptFullName, "\"))
Set Analyzer = WScript.CreateObject("CATC.USBTracer")
Set RecOptions = Analyzer.GetRecordingOptions
RecOptions.SetPostTriggerPercentage 60 ' 60%