7 ianalyzer::stoprecording, Ianalyzer::stoprecording – Teledyne LeCroy USB Analyzer Automation Manual User Manual

Page 17

Advertising
background image

Teledyne LeCroy Automation API Reference Manual for USBTracer, USB Advisor, and Voyager USB Protocol
Suite

17

2.1.7 IAnalyzer::StopRecording


HRESULT StopRecording (

[in] BOOL abort_upload );

Stops a recording started by the StartRecording

method.

Parameters

abort_upload

TRUE, if caller wants to abort upload,

no trace file is created.

FALSE, if you want to upload the recorded trace

Return values

ANALYZERCOMERROR_EVENTSINKNOTINSTANTIATED

Event sink was not instantiated.

ANALYZERCOMERROR_UNABLESTOPRECORDING

Error stopping recording

Remarks

Stops recording started by the

StartRecording

method. The event is issued when recording is

actually stopped (via

_IAnalizerEvents

interface), if the parameter of method call was FALSE.

Example


VBScript:

<OBJECT

RUNAT=Server
ID = Analyzer
CLASSID = "clsid:0B179BB3-DC61-11d4-9B71-000102566088"

>
</OBJECT>
<SCRIPT LANGUAGE="VBScript">
<!--
Sub BtnStopRecording_OnClick

On Error Resume Next

Analyzer.StopRecording True

If Err.Number <> 0 Then

MsgBox Err.Number & ":" & Err.Description

End If

End Sub
-->
</SCRIPT>


C++:

IUsbAnalyzer* usb_analyzer;
. . .
try
{

usb_analyzer->StopRecording( FALSE )

}
catch ( _com_error& er)
{

if (er.Description().length() > 0)
::MessageBox( NULL, er.Description(), _T("UsbAnalyzer client"), MB_OK );
else
::MessageBox( NULL, er.ErrorMessage(), _T("UsbAnalyzer client"), MB_OK );
return 1;

}