9.4 Save Timing Shot in EEPROM
Table 9-6. Save Timing Shot In EEPROM
STEP
OPERATION
ACTION
DISPLAY
1
SELECT SAVE/RECALL MENU.
PRESS #3 KEY.
1 ANALYSIS POINTS
2 MEASUREMENT UNITS
3 SAVE / RESTORE
4 NEXT PAGE
2
SELECT SAVE MENU.
PRESS #3 KEY.
1. SAVE SHOT
2. RECALL SHOT
3. SHOT DIRECTORY
4. ERASE SHOT
3
SELECT SAVE SHOT.
PRESS #1 KEY.
SAVE SHOT # XXXX
TEST: CLOSE
DATE: MM/DD/YY HH:MM
"ENTER" TO CONFIRM
4
CONFIRM SAVING SHOT.
PRESS "ENTER"
KEY.
SAVE IN PROCESS
PLEASE WAIT
5
RETURN TO MAIN MENU.
PRESS ANY KEY.
1. TIME BRKR
2. GET RSLT
3. SET UP
4. DIAGNOSTIC
Notes
Timing shot storage capability varies, depending upon the size of the shots.
The CT-7500 will assign an ID for each of the shots stored in EEPROM.