Operating Procedures

VBT-80P

4

1.0 INTRODUCTION

1.2 General Description

The VBT-80P is a lightweight DC vacuum bottle tester made by Vanguard Instruments
Compa

ny.

The

VBT-

80P

t

e

s

t

s

a

va

c

uum

bot

t

l

e

s

i

nt

egr

i

t

y

by

a

ppl

yi

ng

a

DC

vol

t

a

ge

a

cr

os

s

t

he

bot

t

l

e

unde

r

t

e

s

t

.

A

s

i

mpl

e

PASS”

or

FAI

L”

me

s

s

age

i

ndi

ca

t

e

s

t

he

c

ondi

t

i

on

of

t

he

bot

t

l

e

af

t

e

r

each test.
The VBT-80P is rugged and field-portable. It is easy to operate and requires little training for
first-time users. Operating the VBT-80P only requires connecting the test leads to the vacuum
bottle, selecting the desired test voltage, current threshold, and test time duration, then initiating
the test. A keypad with 16 alphanumeric keys allows the user to control and enter circuit breaker
test data. A built-in thermal printer produces test results on 2.5-inch-wide thermal paper. The
VBT-80P test records can be stored in its FLASH EEPROM memory. Up to 84 records (of 16
r

e

a

di

ngs

ea

c

h)

c

a

n

be

s

t

or

e

d

i

n

t

he

VBT-

80P’

s

me

mor

y.

1.3 Functional Description

Using a voltage multiplier, the VBT-80P generates a programmable test voltage from 10,000Vdc
to 80,000Vdc in 1,000Vdc steps.
The test voltage can be applied for different time durations: 5 seconds, 10 seconds, 30 seconds, 1
mi

nut

e

,

or

2

mi

nut

e

s

.

The

c

ur

r

e

nt

t

hr

ough

t

he

bot

t

l

e

i

s

moni

t

or

e

d

by

t

he

VBT-

80P’

s

c

i

r

c

ui

t

r

y

during a test. If this test current exceeds a preset threshold, the test is terminated and a test

FAI

L”

me

s

s

age

wi

l

l

be

di

s

pl

aye

d

on

t

he

LCD.

The

TEST

FAI

L”

i

ndi

c

a

t

or

wi

l

l

a

l

s

o

be

illuminated on the front panel.
The over current threshold can be programmed for 100 micro-amps, 200 micro-amps, or 300
micro-amps.
A test is considered successful if the selected test voltage was applied for the entire test time and
the test current did not exceed the preset threshold.
The

VBT-

80P’

s

LCD

di

s

pl

ays

a

PASS”

me

s

s

age

a

l

ong

wi

t

h

t

he

t

e

s

t

vol

t

age

a

nd

t

e

s

t

dur

a

t

i

on

i

f

a

t

e

s

t

i

s

s

uc

c

e

s

s

f

ul

.

The

PASS”

a

nd

FAI

L””

me

s

s

age

ca

n

be

pr

i

nt

e

d

on

t

he

bui

l

t

-

i

n

t

he

r

ma

l

printer.

1.4 Furnished Test Accessories

The VBT-80P is supplied with one 10-foot long high-voltage test cable, one 10 foot long
voltage-return lead with alligator clamps. A Ground cable, power cord, and a shipping case are
also included with each VBT-80P.

Note

The VBT-80P high voltage cable can be replaced in the field. Do not remove this HV cable from
the connector except for cable replacement.

Advertising