Symptom

Possible Cause(s)

Corrective Action

Low pressure (cont.)

3 Air leak in inlet plumbing

3 Disassemble, reseal and reas-

semble

4 Relief valve stuck, partially

plugged or improperly
adjusted valve seat worn

4 Clean and adjust relief valve;

check for worn or dirty valve
seats

5 Worn packing. Abrasive

in pumped in cavitation.
Inadequate water

5 Install proper filter suction at

inlet manifold must be limited to
lifting less than 20 feet of water
or 8.5 psi vacuum

6 Worn inlet, discharge valve

blocked or dirty

6 Replace inlet and discharge valve

Pump runs extremely
rough, pressure very
low

1 Inlet restrictions and/or air

leaks.

1 Clean out foreign material

2 Stuck inlet or discharge

valve

2 Replace worn valves

Water leakage from
under manifold

Worn packing or cracked
plunger

Install new packing or plunger

Slight leak, oil leak-
ing in the area of
crankshaft

1 Worn crankshaft seal or

improperly installed oil seal
o-ring

1 Remove oil seal retainer and

replace damaged 0-ring and/or
seals

2 Bad bearing

2 Replace bearing

Excessive play in the
end of the crankshaft
pulley

Worn main bearing from
excessive tension on drive
belt

Replace crankcase bearing and/or
tension drive belt

Water in crankcase

1 Humid air condensing into

water inside the crankcase

1 Change oil intervals

2 Worn packing and/or

cracked plunger

2 Replace packing. Replace

plunger

Loud knocking noise
in pump

1 Cavitation or sucking air

1 Check water supply is turned on

2 Pulley loose on crankshaft

2 Check key and tighten set screw

3 Broken or worn bearing

3 Replace bearing

Troubleshooting (cont.)