Plunger pumps, Rmv series pumps, North america – Vortexx RMV Series User Manual

Page 7: Service pumps (continued)

Advertising
background image

Plunger Pumps

Operating Instructions and Parts Manual

RMV Series Pumps

First Choice When Quality Matters

NORTH

AMERICA

6. Inspect for any debris or damage.

7. Remove the valve O-ring.

Assembly:

1. Install the valve seat

O-ring squarely into
the bottom of the
manifold.

(See figure 11)

2. Insert the valve

assembly and push
squarely into the O-
ring. (See figure 12)

3. Install the high-pressure

packing by placing it into
the cylinder at an angle and then
pushing into place.

NOTE: The point of the “V” or
flat side of the packing is pointed
at you.

4. Lubricate the packing retainer

O-ring with a light film of oil and
install it into the cylinder.

5. Push it completely into

place.(See figure 13)

NOTE: The O-ring
will seat just inside the
manifold and you will hear a
slight pop.

6. Insert the low

pressure seal by
placing it into the
cylinder in at an
angle and pushing it into
place. (See figure 14)

Service Pumps (Continued)

3. Install the valve cap and

torque to the proper
specifications. (See
figure 6)

Inlet Valves:

Disassembly:

1. Remove the manifold.

2. Remove low

pressure seals, insert
screwdriver under
seal lip and lift up.
(See figure 7)

3. Using a reversible

pliers, carefully remove
the packing retainers
(plunger guides). (See
figure 8)

NOTE: You do not want
to damage these so they can be
reused if not worn.

4. Remove the high-

pressure packing by
pulling straight out
with your finger.
(See figure 9)

5. Pull out the valve

cage/head ring
assembly, valve
poppet, spring and
O-ring.

(See figure 10)

Figure 6

Figure 7

Figure 8

Fig-

Figure 12

Figure 11

Figure 10

Figure 13

Figure 14

Advertising