Cbc-1000 diagnostic tests – Warner Electric CBC-1550AHFC User Manual

Page 14

Advertising
background image

14

Warner Electric • 800-825-9050

819-9050

CBC-1000 Diagnostic Tests

t0:

Keyboard Test: Tests the function of the front panel keys.

Press to begin test. RUN: will be displayed. Press each front panel key except to test key.

The display will indicate if the key is functional.

t1:

Non-Volatile RAM Test: Tests CBC-1000 RAM.

Press to begin test. The test will return PASS or FAIL. Press to continue.

t2:

Input Test: Tests whether CBC-1000 is accepting inputs.

Press to begin test. Activate inputs to control. If the input is received, a character will be displayed.

"Ab" - Encoder input, "1" - Start, "2" - Stop, "3" Continuous mode, "4" Reset. Press to continue.

t3:

Output Test: Used to determine whether CBC-1000 outputs are functional.

Press to begin test. Press keys 1-6 on the front panel. The corresponding output will turn on and

latch. Use a VOM to check for a high level state on terminal strip of CBC-1000. Press to exit test.

t4:

Display Test: Tests function of each LED on front panel.

Press to begin test. Each digit of front panel display will automatically be turned on. Check for

faulty LEDs. Press to continue.

t5:

Program Memory Test: Tests program memory capability.

Press to begin test. PASS or FAIL will be returned. Press to continue.

t6:

Date Code Test: Displays software date code.

Press to display date code. Press to exit. Continue

t7:

Serial Test: Tests connections with serial data interface module.

Press to begin test. PASS or FAIL will be displayed. Press to continue.

t8:

Factory Default Settings: Returns CBC-1000 to factory settings.

Press to return all program steps to factory default settings.

RUN