819-9050

CBC-1000AH Control Operation

Successful operation will require knowledge of the following definitions and their relationships to the
Timing Diagram below.

Function Key Definitions

Count

The actual move distance, in pulses or scaled into engineering units
(inches, feet, rotations, degrees, etc.), displayed dynamically.

Move Preset

The desired move distance in pulses or scaled into engineering units.
This is the value the operator enters to select a new move distance. It
can also be locked during the RUN mode by simply programming line
6 to "off".

Early Warning

A distance prior to Move Preset at which the early warning output is
activated. Expressed as pulses or engineering units, this output can
be used to accomplish a soft brake (slow down), energize valves, etc.

Batch*

A cumulative batch counter that can be dynamically displayed to show
the number of operations, cycles, etc. When this counter reaches the
value programmed by the Batch Preset (key 7) the Batch Complete
Output (pin 21 on CBC-1000) is activated. The batch counter can be
manually or automatically reset.

Batch Preset*

A programmable batch counter activates the batch complete output
when the value programmed has been reached by the batch (key 6).

Braking Distance

The actual distance required to stop. This value is dynamically updat-
ed to determine the brake actuation point. Factory default is 25 puls-
es or engineering units which is only used for the first cycle after
power-up. After the first cycle the CBC-1000 will tune to the particular
brake being utilized. The amount of cycles needed for tuning depends
on how far the true braking distance value is from the default of 25.

* The batch counter is not factory enabled. To utilize, see "Additional Features" section.

1

COUNT

2

MOV PST

3

E.W.

6

BATCH

7

BCH PST

8

BRK DIS