How to order, Example – Warner Electric PB-120, PB-170, PB-250, PB-400 User Manual
Page 13

13
Warner Electric • 800-825-9050
P-201
• 819-0485
PB-170 Brake
Drawing I-25753
3
1A-3
2
1B
1A-1
1A-2
1A
How to Order:
1. Specify Type of Armature Desired.
2. Specify Bore Size for Item 1A-1 or 1B.
3. Specify Voltage for Item 3.
Example:
PB-170 Brake per I-25753 - 90 Volt, Antibacklash
Armature, 1/4" Armature Hub Bore
These units meet the standards of UL508 and are
listed under guide card #NMTR2, file #59164.
These units are CSA certified under file #LR11543.
Item
Description
Part Number
Qty.
1A
Armature and Hub
1A-1
Armature Hub
1
1/4" Bore
5102-541-002
5/16" Bore
5102-541-003
3/8" Bore
5102-541-004
1A-2
Armature
110-0111
1
1A-3
Release Spring
808-0019
1
1B
Antibacklash Armature
1
1/4" Bore
5623-111-008
5/16" Bore
5623-111-009
3/8" Bore
5623-111-010
2
Mounting Accessory
5102-101-001
1
3
Magnet
1
6 Volt
5375-631-003
24 Volt
5375-631-005
90 Volt
5375-631-007