PB-250 Flange Mounted Brake

Shaft Sizes

.375 – .750

Static Torque

70 lb. in.

Maximum Speed

7,500 rpm

Standard Voltage

D.C. 6, 24, 90

Customer Shall Maintain:

1. Squareness of brake mounting face with

armature hub shaft within .006 T.I.R.

2. Concentricity of brake mounting pilot

diameter with armature shaft within .010 T.I.R.

Bore and Keyway Dimensions

Armature
Bore Dia.

Keyway

.376/.375

.093 x .046

*.438/.437

.501/.500

.125 x .062

*.563/.562

.626/.625

*.688/.687

.187 x .093

.751/.750

* Available on special order only.

Armature View

Field View

1.063

1.061

Pilot Dia.

Anti. Arm.

.062

.171 (Std.)

.187 (Anti.)

.687 (Std.)

.718 (Anti.)

.437

Max.

#8-32

UNC-3A

.203 Min.

1.187

.015 When New

.343 Max.

K

Std. Arm.

1.390

2.625

Max.

Dia.

1.250

1.078

.718

1.968 (Std.)

1.984 (Anti.)

Antibacklash

Armature

Std. Armature

For Bore & Keyway

sizes see chart below.

45°

24°

.437

Max.

12°

.437 Max.

3.500/3.498 Pilot

Diameter

2.625 Sq.

.204/1.87 diameter (4) holes equally

spaced on 3.125 diameter

*Mounting holes are within .010 of true position relative to pilot
diameter.

.015

Advertising