Chapter 5 MXT 300 Controls

TRAC TOGGLE

TRAC Toggle

The TRAC toggle selects the type of ground

mineral rejection (ground balance) and automatic

tracking to ground mineral changes best suited to

the specifi c area. Three different positions each for

a specifi c ground condition (ground type) are pro-

vided.

The Ground position is used for normal or typical

ground conditions. In this position the MXT 300

will quickly compensate for ground minerals in a

few pumps of the search coil over the ground being

searched and quickly (automatically) track to any

ground changes as you sweep the search coil during

searching. For most operators the Ground position

will be used for over 90% of your searching condi-

tions.

The Lock position monitors, however, doesn't track

to changing ground conditions. Man made iron

decomposes to the point of tricking the Ground and

Salt position tracking into thinking it is a mineral-

ized part of the ground. This can create noise and

instability during searching as the tracking system

bounces radically up and down the scale, always

searching for a good ground rejection setting and

is never able to fi nd it. This makes it diffi cult for

an operator to recognize worthwhile targets and/or

run at the higher performance GAIN settings. In

these conditions it is recommended to fi rst go to the

Ground position and pump the search coil over a

clean area of ground representative of the area (free

of man made iron) then switch the TRAC control to

Lock. By doing so stability and success searching

these trashy areas will improve dramatically. Be-

cause ground changes are monitored during Lock,

once an operator switches back to either Ground or

Salt tracking positions, updates to an appropriate

ground setting are virtually instantaneous.