Seite7, Additional features of vz-7d / vz-5d, Serial control input, rs 232 – WolfVision VZ-5F User Manual

Page 7: Vz-7d only) digital zoom, Vz-7d, vz-5d) manual white balance, Vz-7d only), Slide drawer

Advertising
background image

First make sure that you remove any object from the working
surface (very important!). Then insert a slide in the slide drawer.
The camera automatically recognizes the slide and focuses on
the slide.

In case the slide is out of focus:
- Make sure that the slide is firmly in place
- Make sure that the ZOOM is not in the maximum tele
position (=smallest picture). Use the ZOOM-keys (10).

Serial control input, RS 232

(VZ-7D only)

Digital Zoom

(VZ-7D, VZ-5D)

Manual white balance

(VZ-7D only)

A detailed description of the serial protocol can be found on our internet homepage:

www.wolfvision.com

ADDITIONAL FEATURES OF VZ-7D / VZ-5D

Slide Drawer

(VZ-7D only)

(This is a new function of the VZ-7D which can only be found on units produced after June 2000.)

camera
head

slide

7

All portable Visualizers have an optical 12 x zoom lens. In addition the VZ-7D and the
VZ-5D have a 2x digital zoom extension, which increases the overall zoom range to
24 x zoom. The smallest pickup size on the working surface without (!) digital zoom is 23 x
31mm (0.9"x1.2"). When you zoom in further the digital zoom is automatically activated and
the smallest pickup size is 12x16mm (0.5"x0.6").
However please be aware that when the digital zoom is used the resolution of the picture is
not as good as before.

Automatic white balance adjustment is described on page 5. For some applications you
may require a manual white balance setting. This can be done by pressing the LIGHT-key
(6) for 3 seconds. When the unit is switched off and on again it is set back to automatic
white balance.
(Other white balance settings for specialists see page 24 - for experienced users only)

The serial port can be used to control the Visualizer through an
external device, like a remote control system for a whole
conferencing room.
It can also be used to control the Visualizer through a computer.
A special Windows-software for PC is available from WolfVision.

Pins: 2: RX, 3: TX, 5: GND, 7: RTS, 8: CTS
Baud rate: 19200 or 9600, databits: 8, stopbit: 1, parity: no

Please note that DecimaI-Codes (=ASCII-Codes or Hex-Codes)
must be sent as one single byte (e.g. 199 and not: 1 + 1 + 9) !

Function: Decimal-Code :
Image on
Iris open
Focus far
Zoom wide
Image off
Iris close
Focus near
Zoom tele
Preset 1
Preset 2
Save Preset 1
Save Preset 2
Preset max. wide
Preset A5
Preset A6
Preset max. tele

192
193
194
195
196
197
198
199
202
203
216
217
229
231
232
235

9-pin D-Sub connector on unit