Temperature Control Programming Procedure

OVEN SERVICE PROCEDURES

SP

260˚C/500˚F

nnn

311/5

AL

315˚C/600˚F

HSA

.1

Pb

4.0

ti

5.0

td

.00

1P

30

C

2

rL

204˚C/400˚F

rH

310˚C/590˚F

OLH

100

tOL

InF

Figure 3

P1

2˚C/10˚F

P2

0

P3

315˚C/600˚F

P4

r

P5

1

P6

H.A.

P7

d

P8

OFF

P9

0

P10

100

P11

311

P12

7

Figure 2

Read the entire instruction before programming.

TIP

Configuration Button Functions
<FUNC> =The new setting of the selected parameter is

stored and the display advances to the next

parameter. This is required between each

parameter.

UP= Increases the setting of the selected parameter.

DOWN=Decrease the setting of the selected parameter.

1. Open V2 switch for Basic Configuration (Figure 1)

 Remove instrument from its case
 Open switch V2
 Re-insert the instrument back in its case

2. Basic Configurations

Using the configuration buttons, scroll through

parameter codes, changing them to match (Figure 2)

 After P12 _._._._. Will appear

3. Close V2 switch after Basic Configuration (Figure 1)

 Remove instrument from its case
 Close Switch V2
 Re-insert the instrument back in its case
 Error 400 will appear. Press and hold the and
to

clear

 000 will appear

4. Advanced Configurations Procedure

 Scroll through the parameter codes to nnn. Change

nnn to 311 to unlock the advanced configuration

 Using the configuration buttons, scroll through

parameter codes, changing them to match Figure 3

 Scroll through the parameter codes again and

change the nnn to 5. This locks the advanced con-

figuration
 Scroll through the parameter codes again and verify

nnn is ON