Hood service procedures – XLT XD-9007A (ELEC Oven Version – C, AVI Hood Version – C) User Manual
Page 20

20
Technical Support US: 888-443-2751
Technical Support INTL: 316-943-2751
HOOD SERVICE PROCEDURES
Complete VFD ma
.
Hitachi X200 Restoring AVI Defaults
Access program parameters by pressing the <FUNC> button one time and using the up and down
arrow buttons to navigate to the appropriate parameter press the <FUNC> button again to make
adjustments to that parameter by using the up and down arrows. To store the new settings press the
<STR> button one time.
B031 = 01
B084 = 01
Press and hold the <FUNC> <Down Arrow> and <Stop/Reset> buttons all at the same
time. Release the buttons all at once and the country code should appear in the dis-
play (USA). Hitachi’s factory settings are now restored.
To install AVI Defaults press <FUNC> button one time and enter following parameters
A001 = 01
A003 – USA = 60 Hz.
World = 50 Hz.
A082 = Supply voltage at
location 200, 215, or
230 choose appropriate
voltage.
A093 = 3000
A094 = 01
A096 = 10
B002 = 25
C001 = 02
C002 = 03
C003 = 04
C004 = 05
C014 = 00
F001 = See Figure 1
H004 = 4
B031 = 03
Put controller into display mode by pressing the <FUNC> button and holding until d001 appears
on the display release and then press the <FUNC> button one time. The display should show
0.0.
Test run the motor by turning on one of the oven/hood switches located on the face of the hood.
Read the entire instruction before programming.
TIP