IEI Integration TANK-820-H61 v2.03 User Manual

Page 91

Advertising
background image

TANK-820-H61 Em b e d d e d S ys te m

P a g e 78

Aptio Setup Utility – Copyright (C) 2011 American Megatrends, Inc.

Advanced

Smart Fan Mode Configuration

Smart Fan control

[Auto PWM Mode]

Temperature of Off

75

Temperature of Start

80

Start PWM

30

Slope(Duty Cycle)

[4]


System Smart Fan control

[Auto Duty-Cycle Mode]

First Boundary Temperature

60

Second Boundary Temperature

50

Third Boundary Temperature

40

Fourth Boundary Temperature

30


Smart Fan Mode Select



--------------------
: Select Screen
↑ ↓: Select Item
Enter

Select

+/-: Change Opt.
F1: General Help
F2: Previous Values
F3: Optimized
Defaults
F4: Save & Exit
ESC: Exit

Version 2.14.1219. Copyright (C) 2011 American Megatrends, Inc.

BIOS Menu 16: FAN Configuration

 Sm art Fan co n tro l [Au to PWM Mo d e]

Use the Smart Fan control BIOS option to configure the CPU Smart Fan.

Full Mode

Fan is on all the time

Manual PWM Mode

The fan spins at the speed set in the manual

setting

Auto PWM Mode

D

EFAULT

The fan adjusts its speed using these

settings:

Temperature of Start

Temperature of Off

Start PWM

Slope (Duty Cycle)

 Tem p eratu re o f Off [75]

WARNING:

Setting this value too high may cause the fan to speed up only when

Advertising