UPC-12A/GM45 Panel PC

Page 131

NOTE:

When exiting a program it is necessary to disable the Watchdog Timer,

otherwise the system resets.

Example program:


; INITIAL TIMER PERIOD COUNTER
;
W_LOOP:

MOV AX, 6F02H

;setting the time-out value

MOV BX, 05

;time-out value is 5 seconds

INT 15H
;
; ADD THE APPLICATION PROGRAM HERE
;
CMP EXIT_AP, 1

;is the application over?

JNE W_LOOP

;No, restart the application


MOV AX, 6F02H

;disable Watchdog Timer

MOV BX, 0

;

INT 15H
;
; EXIT ;