JP6 COM4
Pin-9
Setting
1-2
12 V
3-4
RI
5-6 5
V
Table 4-10: COM4 RI and Voltage Selection Jumper
JP8 COM5
Pin-9
Setting
1-2
12 V
3-4
RI
5-6 5
V
Table 4-11: COM5 RI and Voltage Selection Jumper
4.5.6 COM5 RS-232/422/485 Settings
To enable RS-232, RS-422 or RS-485 on COM5, all the following jumpers should be
setup.
4.5.6.1 COM5 RS-232/422/485 RX Select (J2)
Jumper J2 sets the COM5 serial port as RS-232, RS-422 or RS-485.
J2 DESCRIPTION
1-2
RS232 (default)
3-4 RS422
5-6 RS485
Table 4-12: COM5 RS-232/422/485 RX Select
4.5.6.2 COM5 RS-422/485 TX Select (J3)
Jumper J3 sets the COM5 serial port as RS-422 or RS-485.
J3 DESCRIPTION
1-3, 2-4
RS422
3-5, 4-6
RS485
Table 4-13: COM5 RS-422/485 TX Select