Operation, Air compressor controls (22 thru 24) – Lincoln Electric IM10103 AIR VANTAGE 700 (AU) User Manual

Page 26

Advertising
background image

b-6

OPERATION

b-6

AIR COMPRESSOR CONTROLS (22
ThRu 24)

22. COMPRESSOR ON/OFF SWITCh

Turns compressor on and off by activating or
deactivating the electromagnetic compressor
clutch.

23. COMbINED GAuGE (2 FuNCTIONS)

1. COMPRESSOR PROTECTION LIGhT

The yellow compressor protection light remains
off with proper compressor oil temperatures. If the
lights turn on, the compressor protection system
will deactivate the compressor clutch and put the
system in standby mode until the temperature
reaches allowable limits. Check for proper com-
pressor oil level.

2. COMPRESSOR hOuR METER

The compressor hour meter displays the total
time that the compressor has been running (com-
pressor switch must be on).

24. AIR DISChARGE VALVE

Controls flow of compressed air. A 3/4” NPT
(National Pipe Thread) fitting is provided.

25. bATTERY DISCONNECT SWITCh

Battery disconnect switch provides lockout/tagout
capability. Switch is conveniently located on the
front bottom of the machine.

26. ThERMAL LIGhT

This status light indicates the Power Source has
been driven into thermal overload. Welding out-
put shuts off to protect the welding system com-
ponents and resets when the overload condition
is resolved. The Engine and Air Compressor will
continue to operate.

AIR VANTAGE

®

700 (Au) CuMMINS

Advertising