INSTALLATION

ACTIV8™

A-7

ACROSS THE ARC SET-UPS

CC Power Sources with Output Terminals Always
Hot (See Figure A.4)

If the power source has a Remote/Local switch, place
the switch in the Local position.

Place the CV/CC switch in the feeder in the "CC" posi-
tion.

CV

Power Sources with Stud Connectors and

Remote/Local Switch (See Figure A.5)

Place the power source Remote/Local switch in the
Local position.

Place CV/CC switch in the feeder in the "CV" position.

K#

K2999-1

KP1696-XX
KP1697-XX

See Magnum Literature

K1803-XX

Description

ACTIV8™

Drive Roll Kit

Welding Gun

CC power Source

Welding Cables

POWER SOURCE TO ACTIV8™
CABLE CONNECTION DIAGRAMS

K#

K2999-1

KP1696-XX
KP1697-XX

See magnum Literature

K1803-XX

K484

Description

ACTIV8™

Drive Roll Kit

Welding Gun

CV power Source

Welding Cables

Jumper Plug kit

Work clip

Work

Electrode

ACTIV8™

CC Power Source

Classics
Big Red’s
Eagle 10,000 Plus
Pipeliner 200D Without Wire Feed module
SAE’s Without CV Adapter

Work clip

Work

Electrode

Jumper

CV-400
CV-655
DC-400
DC-600
DC-655
V450-Pro

SAE 400 with CV adapter

Engine Driven welder with
Wire Feed Module

Ranger 250 GXT

ACTIV8™

FIGURE A.4

FIGURE A.5