TROUBLESHOOTING

E-2

ACTIV8™

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

PROBLEMS

(SYMPTOMS)

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

The feeder does power up - no voltage,
no cold feed.

The wire feeder power up but there is no
output when the trigger is pulled. The
shielding gas is flowing and the drive
rolls turn.

No shielding gas, or low shielding gas
flow.

Inconsistent wire feeding or wire not
feeding but drive rolls turning.

1. The work lead is disconnected or is a

poor electrical connection.

2. The power source is OFF.

1. The contactor coil connections are

loose.

2. The contactor has failed.

1. The gas supply is OFF or empty.

2. The gas hose is cut or crushed.

3. Dirt or debris is in the solenoid.

4. There is a loose solenoid connection.

5. The solenoid has failed.
6. Dirt or debris in the shielding gas filter.

1. The gun cable is kinked and/or twisted

2. The wire is jammed in the gun and

cable.

3. The gun liner is dirty or worn.

4. The electrode is rusty or dirty.

5. The contact tip is partially melted or

has spatter.

6. Improper gun liner, tip, drive rolls

and/or inner wire guide.

7. Incorrect tension arm pressure on the

drive rolls.

8. The spindle brake is too tight.

9. Worn drive roll.

1. Connect the work lead to the work in a

location free of dirt, rust and paint.

2. Turn ON the power source.

1. Verify the contactor coil connections.

2. Replace the contactor.

1. Verify the gas supply is ON and flow-

ing.

2. Route the gas hose so it avoids sharp

corners and make sure nothing is on
top of it. Repair or replace damaged
hoses.

3. Apply filtered shop at 80psi to the

solenoid to remove dirt.

4. Check that all connections are in good

condition.

5. Replace the solenoid.
6. Remove the shielding gas filter. Apply

filtered shop air at 80 psi to the outlet
(male thread side) of the shielding gas
filter. Replace the shielding gas filter if
needed.

1. Keep the gun cable as straight as pos-

sible. Avoid sharp corners or bends in
the cable.

2. Remove the gun from the wire feeder

and pull the jammed wire out of the
gun and cable.

3. Blow dirt out of the liner with low pres-

sure (40psi or less). Replace the liner
if worn.

4. Use only clean electrode. Use quality

electrode, like L-50 or L-56 from
Lincoln Electric.

5. Replace the contact tip.

6. Verify the proper parts are installed.

7. Adjust the tension arm per the

Instruction Manual. Most electrodes
feed well at a tension arm setting of "3".

8. Verify the spool of wire moves with

minimal effort.

9. Replace the drive rolls if worn or filled

with dirt.