Note: Troubleshooting problems may have similar causes and solutions.

Close drain valve

Tank drain valve is open

Check fittings with soapy water. Tighten or reseal leaking fittings.
DO NOT OVERTIGHTEN.

Fittings Leak

Make sure air inlet vents are not covered or restricted.

Restricted air intake

Decrease amount of air used.

Prolonged excessive use of air

Check air requirement of accessory. If it is higher than CFM and
pressure supplied by compressor, you need a larger compressor.
Most accessories are rated at 25% of actual CFM while running
continuously.

Compressor not large enough

Check and replace if necessary.

Hole in air hose

Immediately replace tank. DO NOT attempt to
repair.

Tank leaks

Replace compressor assembly.

Valve leaks

Replace compressor assembly.

Leaking or worn piston

Replace compressor assembly.

Blown seals

If pressure drops too low, adjust regulator while accessory is used.

This is normal

Check air requirement of accessory. If it is higher than CFM and
pressure supplied by compressor, you need a larger compressor.
Most accessories are rated at 25% of actual CFM while running
continuously.

Compressor not large enough

SOLUTION

POSSIBLE CAUSE

Low pressure or not
enough air
or
Compressor does not
stop

Regulated pressure
gauge reading drops
when air accessory is
being used

PROBLEM

WARNING

:

Replace pressure switch

Tank pressure exceeded normal
operating pressure

Replace pressure switch

Pressure switch stuck

Motor will start automatically when tank pressure drops below
kick-in pressure of pressure tank.

Tank pressure exceeds preset
pressure switch limit

To reset the motor overload, toggle the ON/OFF switch to the
“OFF’ position and unplug the unit from the power outlet. Allow a
minimum of 10 minutes for motor overload cut-out to cool and
reset. Unit can then be plugged in and restarted.

Motor overload protection has
tripped

• Reset circuit breaker. Do not use circuit breaker with higher rating
than specified for your branch circuit.

Circuit breaker tripped

• Check for low voltage and proper extension cord size.
• Disconnect other applications from circuit. Operate compressor

on a dedicated circuit.

Remove and clean or replace.

Check valve stuck open

Check for proper gauge and extension cord length.

Wrong wire gauge in cord or
excessive extension cord length

Contact authorized service center.

Loose electrical connections

Have checked at service center. Do not operate compressor in the
paint spray area

Paint spray on internal motor
parts

Have checked at service center.

Possible defective motor

Pressure relief valve
opens

Motor will not run

TROUBLESHOOTING CHART

Allow compressor to cool for approximately 30 minutes so thermal
overload switch will reset. Make sure compressor is run in a clean,
well-ventilated area where temperature will not exceed 100°F.

Motor overheated