Correct Anchorage Positioning:

This chart details allowable working zones required

to reduce risk of swing falls and improper side loading.

ALWAYS adhere to information specified by chart.

Anchor Distance

From

Leading Edge (Y)

Working Distance

Along Roof Edge

(Either Direction) (X)

Working Angle

From

Perpendicular (Ø)

6’

10’
15’
20’
25’
30’
35’
40’
45’
50’
55’
60’

8’

9’ - 9”

11’ - 7”

13’ - 3”

14’ - 6”

16’

17’ - 2”
18’ - 3”

19’ - 4”

19’ - 10”

21’ - 4”
22’ - 3”

53°
45°
38°
33°
30°
28°
26°
24°
23°
21°
21°
21°

For example, if the anchorage connector is 6’ from the leading

edge (Y), the working distance (X) is 8’ in each direction from

the perpendicular, which translates to a 53° working angle.