Airvantage servicing - poppet valve drawing, Exp view – Versa-Matic 2 Bolted Metallic Hazardous Service Ball Valve (RE2 ) User Manual

Page 31

Advertising
background image

re2mdlAsmATEX-rev0614

www

.

versamatic

.

com

3: EXP

VIEW

Model RE2 Metallic Bolted •

28

Note: Refer to AirVantage Composite Repair

Parts List on page 23 for part numbers

CAPSCREW, HEX SOC, M6 X 35mm

COVER

SEAL, O-RING

VALVE, SOLENOID

VALVE, POPPET

SEAL, O-RING

CONTROL MODULE

O-RING

CAP, SWITCH

POWER GENERATOR MODULE

CAPSCREW, HEX SOC, M6 X 25mm

SEAL, O-RING

CAPSCREW, HEX SOC, M6 X 25mm

SEAL, O-RING

COVER

CAPSCREW, HEX SOC, M6 X 35mm

O-RING

O-RING

REGULATOR

WASHER, FLAT, M6

WASHER, FLAT, M6

Do not open when an

explosive atmosphere

may be present.

WARNING

S u b s t i t u t i o n o f

components may

impair intrinsic safety.

WARNING

Note: Ensure all mating faces are free from scores or damage prior to

re-assembly. Check each metallic face joint with a 0.003" feeler gage

to ensure all flange faces are fully closed after assembly. Failure to do

so may compromise the flameproof design of the assembly.

AirVantage Servicing - Poppet Valve Drawing

Advertising