Step #1: Remove the Patch Cable
Twist the ribbed portion of the patch cable connector

in a counterclockwise direction, until it unthreads from

the connector. The cable can then be removed from the

intermediate.
Step #2: Remove the AirVantage from the Pump
Use a ½” socket and remove the four 5/16-18 x 5 1/2 cap

screws that hold the AirVantage to the pump. Remove the two

chamber bolts/nuts that are holding the right side bracket to be

able to remove the right bracket and AirVantage unit from the

pump. Be sure to support the weight of the AirVantage while

removing the last cap screw. After the AirVantage is removed

from the pump, set the unit down on the cover located on the

bottom. Inspect the o-ring between the poppet valve and the

adapter plate for damage.
Step #3: Access the Pilot Valve and Pressure Regulator
Use a 5mm hex-key wrench and loosen the four M6 x 35mm

socket head cap screws securing the top cover on. Lift the

cover off, exposing the pilot valve and pressure regulator.

There is a molded o-ring seal located on the underside of the

cap. Make sure the o-ring stays located within the groove.
Unplug the connector attached to it. Use a miniature 4-way

Phillips screwdriver and remove the two screws securing the

pilot valve to the plate. The valve and gasket can now be

removed and/or replaced.
Use slip-joint pliers to unscrew the regulator from the body by

turning it in a counterclockwise direction.
“AirVantage CAUTION” – Do not loosen or tighten the

regulator by turning the knurled portion of the unit. Place

the slip-joint pliers on the smooth area underneath the

knurled area of the regulator.
Reinstall the top cover and loosely reinstall the bolts. Turn the

assembly over and let it now rest on the top cover.
Step #4: Access the Power Generation Module
Use a 5mm hex-key wrench and remove the four M6 x 35mm

socket head cap screws securing the bottom cover on. Lift

the bottom cover off, exposing the power generation module.

There is a molded o-ring seal located on the underside of the

cap. Make sure the o-ring stays located within the groove.
Unplug the connector that connects the power generator to the

control board. Use a 4mm hex-key wrench to loosen the four

M5 x 25mm socket head cap screws. The power generation

module should now be loose. Carefully lift the power

generation module off the rest of the assembly, making sure

that the control board wire and connector slips through the hole

in the power generation case.
Step #5: Access the Control Module
Use a 4mm hex-key wrench and loosen the two M5 x 25mm

socket head cap screws securing the control module to the

poppet assembly. The control module should now be loose.

Carefully lift the control module off the poppet assembly,

making sure that the pilot valve connector wire slips through

the hole in the poppet valve assembly.
The Poppet valve assembly can now be replaced.

Step #6: Reinstallation
Install the control module on the poppet valve assembly. Make

sure to feed the pilot valve connector wire through the hole in

the poppet valve assembly. Install the two M5 x 25mm socket

head cap screws and tighten to 3.4 N-M.
Install the power generation module onto the control module.

Make sure to feed the control module wire through the hole in

the power generation case. Install the four M5 x 25mm socket

head cap screws and tighten to 6.8 N-M.
“AirVantage Caution” – Be sure to reattach the connector

from the power generator to the control board.
Install the bottom cover, making sure the o-ring seal is still in

the groove. Tighten the four M6 screws. The unit can now be

turned over and set on the bottom cover.
Install the pilot valve, tighten the screws snug with a jeweler's

screwdriver.
“AirVantage Caution” – Be sure to reattach the connector

to the pilot valve.
AirVantage Caution” – Be sure to reattach the patch cable

connector that connects the AirVantage module to the

intermediate.
If the pressure regulator needs to be replaced, use slip-joint

pliers to unscrew the regulator from the body by turning it in a

counterclockwise direction.
“AirVantage CAUTION” – Do not loosen or tighten the

regulator by turning the knurled portion of the unit. Place

the slip-joint pliers on the smooth area underneath the

knurled area of the regulator.
Step #4: Reinstallation
Reinstall the top cover, making sure the o-ring seal is still in the

groove. Tighten the four M6 screws.
Reinstall the AirVantage right bracket, chamber bolts/nuts and

four 5/16-18 x 5 1/2 cap screws, torque to 90 in-lbs.
“AirVantage Caution” – Be sure to reattach the patch

cable connector that connects the AirVantage module

to the intermediate.
Refer to Page 27 for Illustration.

Do not open when an

explosive atmosphere

may be present.

WARNING

S u b s t i t u t i o n o f

components may

impair intrinsic safety.

WARNING

Note: Ensure all mating faces are free from scores or damage prior to

re-assembly. Check each metallic face joint with a 0.003" feeler gage

to ensure all flange faces are fully closed after assembly. Failure to do

so may compromise the flameproof design of the assembly.