airVantage Servicing - Pilot Valve & Pressure Regulator

Pilot Valve and Pressure Regulator

To service the pilot valve or the pressure regulator, first shut

off and bleed the air being supplied to the pump. For safety

purposes the air supply line should be disconnected from

the pump. Then shut off the suction and discharge lines to

the pump. Bleed the pressure from the pump suction and

discharge lines and remove the lines from the pump. During

the servicing of the AirVantage, consult the “AirVantage

Composite Repair Parts Drawing”.

Step #1: Remove the Patch Cable

Twist the ribbed portion of the patch cable connector in

a counterclockwise direction, until it unthreads from the

connector. The cable can either be removed from the

intermediate or from the control module.

Step #2: Remove the AirVantage from the Pump

Use a ½” socket and remove the four 5/16-18 x 5 1/2 cap

screws that hold the AirVantage to the pump. Remove the two

chamber bolts/nuts that are holding the right side bracket to be

able to remove the right bracket and AirVantage unit from the

pump. Be sure to support the weight of the AirVantage while

removing the last cap screw. After the AirVantage is removed

from the pump, set the unit down on the plastic cover located

on the bottom. Inspect the o-ring between the poppet valve and

the adapter plate for damage.

Step #3: Access the Pilot Valve and Pressure Regulator

Use a 5/32 hex-key wrench and remove the four 10-32 x .50

socket head cap screws securing the top cover on. Lift the

cover off, exposing the pilot valve and pressure regulator.

There is a molded o-ring seal located on the underside of the

cap. Make sure the o-ring stays located within the groove.

If the pilot valve needs to be replaced, unplug the connector

attached to it. Use a jeweler's screwdriver and remove the

two screws holding the pilot valve to the plate. The valve and

gasket can now be removed and/replaced. When reinstalling

the pilot valve, tighten the screws to snug with a jeweler's

screwdriver.

“AirVantage Caution” – Be sure to reattach the connector

to the pilot valve.

If the pressure regulator needs to be replaced, use slip-joint

pliers to unscrew the regulator from the body by turning it in a

counterclockwise direction.

“AirVantage CAUTION” – Do not loosen or tighten the

regulator by turning the knurled portion of the unit. Place

the slip-joint pliers on the smooth area underneath the

knurled area of the regulator.

Step #4: Reinstallation

Reinstall the top cover, making sure the o-ring seal is still in the

groove. Tighten the four 10-32 screws.

Reinstall the AirVantage right bracket, chamber bolts/nuts and

four 5/16-18 x 5 1/2 cap screws, torque to 90 in-lbs.

“AirVantage Caution” – Be sure to reattach the patch cable

connector that connects the AirVantage module to the

intermediate.