3

Modular L-O-X

®

Air Entry Packages

Air Entry Packages with Control Reliable

Energy Isolation


Model

Air Entry

Port Size

C

V

Dimensions

(inches/mm)

Number

Type

In-Out Exh. 1 to 2 2 to 3

Length

Width

Depth

Cat-2 with SV27

RC208-09

FR

1/2

1

6.3

9.2

14.80 (374.9)

11.00 (279.0)

6.60 (167.7)

Cat-2 with SV27

RC208L-09 FRL 1/2 1

6.3 9.2

14.80 (374.9)

11.00 (279.0)

6.60 (167.7)

Cat-3 with DM

1

Series E

RC304-09

FR

1/4

1/2

1.3

2.4

13.00 (330.0)

11.00 (279.0)

5.40 (134.7)

Cat-3 with DM

1

Series E

RC306-09

FR

3/8 1/2 1.9 2.4

13.00 (330.0)

11.00 (279.0)

5.40 (134.7)

Cat-3 with DM

1

Series E

RC304L-09

FRL

1/4

1/2

1.3

2.4

13.00 (330.0)

11.00 (279.0)

5.40 (134.7)

Cat-3 with DM

1

Series E

RC306L-09

FRL

3/8 1/2 1.9 2.4

13.00 (330.0)

11.00 (279.0)

5.40 (134.7)

Cat-4 with DM

Series E

RC404-09

FR

1/4

1/2

1.3

2.4

13.00 (330.0)

11.00 (279.0)

5.40 (134.7)

Cat-4 with DM

Series E

RC406-09

FR

3/8

1/2

1.9

2.4

13.00 (330.0)

11.00 (279.0)

5.40 (134.7)

Cat-4 with DM

Series E

RC404L-09

FRL

1/4

1/2

1.3

2.4

13.00 (330.0)

11.00 (279.0)

5.40 (134.7)

Cat-4 with DM

Series E

RC406L-09

FRL

3/8

1/2

1.9

2.4

13.00 (330.0)

11.00 (279.0)

5.40 (134.7)

* NPT port threads. Specify voltage and hertz when ordering.

Do not use in power press clutch/brake applications.

Pre-engineered panel-mounted design with air entry via filter and
regulator “FR”, or filter, regulator, and lubricator “FRL”.

Includes 3/2 Normally Closed Sensing Valve which senses poppet position
and state. Electrical feedback via DPST switch (double-pole, single-throw).

Applications include Air Dump and Trapped-Pressure Release.

Air Entry Package with 3/2 Normally Closed

Sensing Valve

Pre-engineered panel-mounted design with air entry via a filter and
regulator “FR”, or filter, regulator and lubricator “FRL”.

Includes DM

Series E Double Valve with Monitoring & Memory:

a) Self-contained dynamic monitoring system requires no further valve
monitoring controls.
b) Dynamic memory of abnormal function prevents unintentional reset with removal
of air or electricity.

All necessary features for safety applications are included:

a) Electrical reset valve
b) Status indicator switch for valve condition (ready-to-run) feedback.

Pre-engineered panel-mounted design with air entry
via a filter and regulator “FR”, or filter, regulator and
lubricator “FRL”.

Includes DM

1

Series E Double Valve with Monitoring:

a) Self-contained dynamic monitoring system requires no further valve
monitoring controls.
b) Ready-to-run: If an abnormality clears itself upon the removal of electricity to both
solenoids, it will be ready-to-run again. It does not remember the abnormality & stay
in a locked-out state until intentionally reset. Therefore, cumulative abnormalities
may go undetected.
c) Status indicator switch for valve condition (ready-to-run) feedback.

Do not use in power press clutch/brake applications.