www.rosscontrols.com

3

Modular L-O-X

®

Air Entry Packages

Air Entry Packages with Control Reliable

Energy Isolation


Model

Air Entry

Port Size

C

V

Dimensions

(inches/mm)

Number

Type

In-Out Exh. 1 to 2 2 to 3

Length

Width

Depth

Cat-2 with SV27

RC208-09

FR

1/2

1

6.3

9.2

14.80 (374.9)

11.00 (279.0)

6.60 (167.7)

Cat-2 with SV27

RC208L-09 FRL 1/2 1

6.3 9.2

14.80 (374.9)

11.00 (279.0)

6.60 (167.7)

Cat-3 with DM

1

Series E

RC304-09

FR

1/4

1/2

1.3

2.4

13.00 (330.0)

11.00 (279.0)

5.40 (134.7)

Cat-3 with DM

1

Series E

RC306-09

FR

3/8 1/2 1.9 2.4

13.00 (330.0)

11.00 (279.0)

5.40 (134.7)

Cat-3 with DM

1

Series E

RC304L-09

FRL

1/4

1/2

1.3

2.4

13.00 (330.0)

11.00 (279.0)

5.40 (134.7)

Cat-3 with DM

1

Series E

RC306L-09

FRL

3/8 1/2 1.9 2.4

13.00 (330.0)

11.00 (279.0)

5.40 (134.7)

Cat-4 with DM

2®

Series E

RC404-09

FR

1/4

1/2

1.3

2.4

13.00 (330.0)

11.00 (279.0)

5.40 (134.7)

Cat-4 with DM

2®

Series E

RC406-09

FR

3/8

1/2

1.9

2.4

13.00 (330.0)

11.00 (279.0)

5.40 (134.7)

Cat-4 with DM

2®

Series E

RC404L-09

FRL

1/4

1/2

1.3

2.4

13.00 (330.0)

11.00 (279.0)

5.40 (134.7)

Cat-4 with DM

2®

Series E

RC406L-09

FRL

3/8

1/2

1.9

2.4

13.00 (330.0)

11.00 (279.0)

5.40 (134.7)

* NPT port threads. Specify voltage and hertz when ordering.

Do not use in power press clutch/brake applications.

•

Pre-engineered panel-mounted design with air entry via filter and
regulator “FR”, or filter, regulator, and lubricator “FRL”.

•

Includes 3/2 Normally Closed Sensing Valve which senses poppet position
and state. Electrical feedback via DPST switch (double-pole, single-throw).

•

Applications include Air Dump and Trapped-Pressure Release.

Air Entry Package with 3/2 Normally Closed

Sensing Valve

•

Pre-engineered panel-mounted design with air entry via a filter and
regulator “FR”, or filter, regulator and lubricator “FRL”.

•

Includes DM

2®

Series E Double Valve with Monitoring & Memory:

a) Self-contained dynamic monitoring system requires no further valve
monitoring controls.
b) Dynamic memory of abnormal function prevents unintentional reset with removal
of air or electricity.

•

All necessary features for safety applications are included:

a) Electrical reset valve
b) Status indicator switch for valve condition (ready-to-run) feedback.

•

Pre-engineered panel-mounted design with air entry
via a filter and regulator “FR”, or filter, regulator and
lubricator “FRL”.

•

Includes DM

1

Series E Double Valve with Monitoring:

a) Self-contained dynamic monitoring system requires no further valve
monitoring controls.
b) Ready-to-run: If an abnormality clears itself upon the removal of electricity to both
solenoids, it will be ready-to-run again. It does not remember the abnormality & stay
in a locked-out state until intentionally reset. Therefore, cumulative abnormalities
may go undetected.
c) Status indicator switch for valve condition (ready-to-run) feedback.

Do not use in power press clutch/brake applications.