Maple Systems MAPware-7000 User Manual
Page 253

MAPware-7000 Programming Manual
253
1010-1040, Rev. 02
+3
Start Date: Hour
0-23
+4
Start Date: Minute
0-59
+5
Start Date: Seconds
0-59
+6
End Date: Day
1-31
+7
End Date: Month
1-12
+8
End Date: Year
0-99
+9
End Date: Hour
0-23
+10
End Date: Minute
0-59
+11
End Date: Seconds
0-59
Group: this is the tag register that the HMC reads to determine
which Data Group to upload. Valid number: 1-4
Start Register For Filename or Filename:
o Select ‘Start Register for Filename’ to reference four
consecutive registers. These registers are interpreted
by the HMC7000 as ASCII characters (two characters per
16-bit register) to create a filename that is used by the
HMC when uploading.
o Select ‘Filename’ to manually enter the name for the
upload file.
StatusRegister: the HMC7000 will use this register to enter a
status code number which can be used to communicate any
errors during upload or status:
Status
Code
Number
Description
3
Error: Logger Group Invalid
5
Error: The File Output Device code is invalid
6
Error: The Start/End Data/Time is invalid
51
Error: The USB Flash Drive not detected
52
Error: Get Descriptor Error
53
Error: Set Address Error