Proface GP4600R - 12.1 Standard HMIs with Rear Mounting Options" User Manual
Page 4
4
RS-232C
RS-422
Unit's Connector
: XM2C-0942-132L<made by OMRON>
Recommended Connector
: XM2D-0901
<made by OMRON>
Recommended Cover
: XM2S-0913
<made by OMRON>
Jack Screw
: XM2Z-0073
<made by OMRON>
Stacking Metal Fittings require #4-40 inch screw.
• This unit does not correspond to RS-422/485 (2 wire) communication.
• This unit does not correspond to Serial Multilink communication.
Pin Arrangement
Pin #
RS-232C
Signal Name
Direction
Meaning
1
CD
Input
Carrier Detect
2
RD (RXD)
Input
Receive Data
3
SD (TXD)
Output
Send Data
4
ER (DTR)
Output
Data Terminal Ready
5
SG
-
Signal Ground
6
DR (DSR)
Input
Data Set Ready
7
RS (RTS)
Output
Request to Send
8
CS (CTS)
Input
Clear to Send
9
NC
-
No connection
Shell
FG
-
Frame Ground
Pin Arrangement
Pin #
RS-422
Signal Name
Direction
Meaning
1
RDA
Input
Receive Data A(+)
2
RDB
Input
Receive Data B(-)
3
SDA
Output
Send Data A(+)
4
ERA
Output
Data Terminal Ready A(+)
5
SG
-
Signal Ground
6
CSB
Input
Send Possible B(-)
7
SDB
Output
Send Data B(-)
8
CSA
Input
Send Possible A(+)
9
ERB
Output
Data Terminal Ready B(-)
Shell
FG
-
Frame Ground
5
1
6
9
5
1
6
9