Proface FP3900 - 19 Flat Panel" User Manual

Page 14

Advertising
background image

• Tightening the screws with too much force can damage the FP unit's case.
• The necessary torque is 0.5N•m.

• Depending on the installation panel's thickness, etc., the number of installation

fasteners used may need to be increased provide the desired level of moisture
resistance.

• Installation fastener model number : GP070-AT01.

FP

Panel

„

„

„

„

„Attach the Installation Fasteners from Inside the Panel

The following figures show the four (4) fastener insertion slot locations. Insert each fastener's
hook into the slot. Tighten the screws in a diagonal pattern, and slowly increase the torque.

Unit: mm [in]

„

„

„

„

„Create a Panel Cut and insert the FP into the panel from the front

Panel

301.5 [11.87 ]

+1
0

+0.04
0

227.5

[8

.9

6

]

+1

0

under 4-R3

FP

+0.04

0

Panel thickness

1.6mm[0.06in] to
10.0mm[0.39in]

Panel

FP

Installation

fastener

Top

Bottom

Insertion Slots

Advertising
This manual is related to the following products: