8) In Read address Address type the first address to which data was copied. In the example, this
is 200.
9) In Max. data records type the number of records to save in a file.
10) Click Data Format…
11) For each item to be
logged in the file:
• Click New…
(046)
• For Data type choose
the data type of the item
being logged. Typically
32-bit Float).
• In Comment Enter a
description for the item
to be logged, for
example “PV 1”.
• Click OK.
(047)
12) Click Exit to close the
Data Format window.
(048)
13) In the History Files
group check one or
more locations to
which to save the data
(Save to USB disk or
Save to HMI
memory).
14) In Folder name type a
name for the folder in
which the data log file
should be created such
as “datalog”.
(049)
Silver Series EM OIT
35