Watlow EZ-ZONE PM Integrated Controller User Manual
Page 113

Watlow EZ-ZONE
®
PM Integrated Controller
•
110
•
Chapter 7 Profiling Page
Profiling Page
Dis-
play
Parameter Name
Description
Range
Default
Modbus
Relative Ad-
dress
CIP
Class
Instance
Attribute
hex (dec)
Param-
eter ID
Data
Type
&
Read/
Write
Ent1]
[Ent1]
Step Type Parameters
Event 1
When Step Type is not Unused
Step, select whether Event
Output 1 or 2 is on or off during
this step.
[`oFF]
Off (62)
[``on]
On (63)
Off
Instance 1
Map 1
Map 2
2582
4512
Offset to next
instance (Map
1 equals +50,
Map 2 equals
+100)
0x79 (121)
1 to 40
7
21007 uint
RWE
[Ent2]
[Ent2]
Step Type Parameters
Event 2
When Step Type is not Unused
Step, select whether Event
Output 1 or 2 is on or off during
this step.
[`oFF]
Off (62)
[``on]
On (63)
Off
Instance 1
Map 1
Map 2
2584
4514
Offset to next
instance (Map
1 equals +50,
Map 2 equals
+100)
0x79 (121)
1 to 40
8
21008 uint
RWE
Note:
Some values will be rounded off to fit in the four-character display. Full values can be read with other
interfaces.
R: Read
W: Write
E:
EEPROM
S:
User Set