Series 146 – Watlow Series 146 Retrofit User Manual

Page 62

Advertising
background image

Series 146

Series 146

Line

Voltage

Input

Temp Range

Control

Mode

Action

Output

Set Point

Mounting

Retrofit control

See Notes

Below

146E-2101-4000

230 VAC

100 ohm DIN

-73 to 600°C

Low Limit

Auto Reset

8A Relay

Integral

DIN Rail

LV E6RZ -073 0600 A

6, 8

146E-2101-4000

230 VAC

100 ohm DIN

-100 to 1112°F

Low Limit

Auto Reset

8A Relay

Integral

DIN Rail

LV E6PZ -100 1112 A

6, 8

146E-2101-4N00

230 VAC

100 ohm DIN

-73 to 600°C

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5RZ -073 0600 A

2, 6, 8

146E-2101-4N00

230 VAC

100 ohm DIN

-100 to 1112°F

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5PZ -100 1112 A

2, 6, 8

146E-2101-4P00

230 VAC

100 ohm DIN

-73 to 600°C

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5RZ -073 0600 A

2, 6, 8

146E-2101-4P00

230 VAC

100 ohm DIN

-100 to 1112°F

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5PZ -100 1112 A

2, 6, 8

146E-2101-4S00

230 VAC

100 ohm DIN

-73 to 600°C

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5RZ -073 0600 A

2, 6, 8

146E-2101-4S00

230 VAC

100 ohm DIN

-100 to 1112°F

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5PZ -100 1112 A

2, 6, 8

146E-2104-1000

230 VAC

1K ohm

-73 to 600°C

High Limit

Manual Reset

8A Relay

Integral

DIN Rail

LV E6RU -073 0600 A

1, 6, 8

146E-2104-1000

230 VAC

1K ohm

-100 to 1112°F

High Limit

Manual Reset

8A Relay

Integral

DIN Rail

LV E6PU -100 1112 A

1, 6, 8

146E-2104-1N00

230 VAC

1K ohm

-73 to 600°C

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV E5RU -073 0600 A

1, 2, 6, 8

146E-2104-1N00

230 VAC

1K ohm

-100 to 1112°F

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV E5PU -100 1112 A

1, 2, 6, 8

146E-2104-1P00

230 VAC

1K ohm

-73 to 600°C

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV E5RU -073 0600 A

1, 2, 6, 8

146E-2104-1P00

230 VAC

1K ohm

-100 to 1112°F

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV E5PU -100 1112 A

1, 2, 6, 8

146E-2104-1S00

230 VAC

1K ohm

-73 to 600°C

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV E5RU -073 0600 A

1, 2, 6, 8

146E-2104-1S00

230 VAC

1K ohm

-100 to 1112°F

High Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV E5PU -100 1112 A

1, 2, 6, 8

146E-2104-2000

230 VAC

1K ohm

-73 to 600°C

Low Limit

Manual Reset

8A Relay

Integral

DIN Rail

LV E6RY -073 0600 A

1, 6, 8

146E-2104-2000

230 VAC

1K ohm

-100 to 1112°F

Low Limit

Manual Reset

8A Relay

Integral

DIN Rail

LV E6PY -100 1112 A

1, 6, 8

146E-2104-2N00

230 VAC

1K ohm

-73 to 600°C

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV E5RY -073 0600 A

1, 2, 6, 8

146E-2104-2N00

230 VAC

1K ohm

-100 to 1112°F

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV E5PY -100 1112 A

1, 2, 6, 8

146E-2104-2P00

230 VAC

1K ohm

-73 to 600°C

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV E5RY -073 0600 A

1, 2, 6, 8

146E-2104-2P00

230 VAC

1K ohm

-100 to 1112°F

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV E5PY -100 1112 A

1, 2, 6, 8

146E-2104-2S00

230 VAC

1K ohm

-73 to 600°C

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV E5RY -073 0600 A

1, 2, 6, 8

146E-2104-2S00

230 VAC

1K ohm

-100 to 1112°F

Low Limit

Manual Reset

8A Relay

Remote

DIN Rail

LV E5PY -100 1112 A

1, 2, 6, 8

146E-2104-3000

230 VAC

1K ohm

-73 to 600°C

High Limit

Auto Reset

8A Relay

Integral

DIN Rail

LV E6RW -073 0600 A

1, 6, 8

146E-2104-3000

230 VAC

1K ohm

-100 to 1112°F

High Limit

Auto Reset

8A Relay

Integral

DIN Rail

LV E6PW -100 1112 A

1, 6, 8

146E-2104-3N00

230 VAC

1K ohm

-73 to 600°C

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5RW -073 0600 A

1, 2, 6, 8

146E-2104-3N00

230 VAC

1K ohm

-100 to 1112°F

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5PW -100 1112 A

1, 2, 6, 8

146E-2104-3P00

230 VAC

1K ohm

-73 to 600°C

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5RW -073 0600 A

1, 2, 6, 8

146E-2104-3P00

230 VAC

1K ohm

-100 to 1112°F

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5PW -100 1112 A

1, 2, 6, 8

146E-2104-3S00

230 VAC

1K ohm

-73 to 600°C

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5RW -073 0600 A

1, 2, 6, 8

146E-2104-3S00

230 VAC

1K ohm

-100 to 1112°F

High Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5PW -100 1112 A

1, 2, 6, 8

146E-2104-4000

230 VAC

1K ohm

-73 to 600°C

Low Limit

Auto Reset

8A Relay

Integral

DIN Rail

LV E6RZ -073 0600 A

1, 6, 8

146E-2104-4000

230 VAC

1K ohm

-100 to 1112°F

Low Limit

Auto Reset

8A Relay

Integral

DIN Rail

LV E6PZ -100 1112 A

1, 6, 8

146E-2104-4N00

230 VAC

1K ohm

-73 to 600°C

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5RZ -073 0600 A

1, 2, 6, 8

146E-2104-4N00

230 VAC

1K ohm

-100 to 1112°F

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5PZ -100 1112 A

1, 2, 6, 8

146E-2104-4P00

230 VAC

1K ohm

-73 to 600°C

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5RZ -073 0600 A

1, 2, 6, 8

146E-2104-4P00

230 VAC

1K ohm

-100 to 1112°F

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5PZ -100 1112 A

1, 2, 6, 8

146E-2104-4S00

230 VAC

1K ohm

-73 to 600°C

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5RZ -073 0600 A

1, 2, 6, 8

146E-2104-4S00

230 VAC

1K ohm

-100 to 1112°F

Low Limit

Auto Reset

8A Relay

Remote

DIN Rail

LV E5PZ -100 1112 A

1, 2, 6, 8

146E-2105-1000

230 VAC

100 ohm DIN

0 to 80°C

High Limit

Manual Reset

8A Relay

Integral

DIN Rail

LV E6RU 0000 0080 A

6, 8

Watlow Controls

3/30/2005

Page 57

Advertising