4.3 Control Panel & Steering Control Levers

The Stander ZK speed and direction are controlled by using the control handles. Moving the control handles
equal distance forward or backward the machine moves in a straight line. By releasing the control handles
during operation, the controls will return to the neutral position and the machine will stop.
1. Forward Control Levers
2. Reverse Control Levers
3. Stationary Handlebar
4. Throttle
5. Choke
6. Digital Hour Meter
7. Ignition Switch
8. PTO Switch









4.4 Fuel System / Fuel Shut Off Valve

The fuel shut-off valve is located on the right side of the upright. The valve should be in the “OFF” position at
all times when the mower is not in use. Do Not fill the tank completely. Fill level is 1 inch below the bottom
of the fill neck. This will allow for the gas to expand.












4.5 Digital Hour Meter

The Stander is equipped with a digital hour meter. Refer to operating/reset instructions below.

The programming specified is:
Default display: Hours
Press once (TMR1): Timer 1, press for 3 sec to reset
Press twice (TMR2): Timer 2, press for 3 sec to reset
Press three times (svc ENG): Will display time remaining until next
service point, hold down to reset. The first interval is 8hr, thereafter
100hr. Beginning 5hr before service point the meter will flash “svc
ENG, in [remaining hours]” every 5 sec.
Shut off engine: Will display how many times the engine has started.

2

1

1

2

3

6

5

4

7

8

3-Way
Valve