1-4

1. ZERO POINT ADJUSTMENT

IMPORTANT

1. Do not turn off the power to the transmitter

immediately after completion of the change in
the LRV (and/or URV) setting(s). Note that
powering off within thirty seconds after setting
will ca use a return to the previous settings.

2. Changing LRV automatically changes URV to

the following value.

URV

ϭ

previous URV

ϩ

(new LRV

Ϫ

previous LRV)

3. If the range-setting push-button and external

zero-adjustment screw are not touched during
a range-change operation, the transmitter
automatically switches back to the normal
operation mode.

F0106.EPS

Integral indicator

Range-setting switch
(Push-button)

Note: Use a thin bar which has a blunt tip, e.g.,

a hexagonal wrench, to press the range-
setting push-button.

Figure 1.2.1 Range-setting Switch