IM 01C22T01-01E

3-1

3. PARAMETER LISTS

3.

PARAMETER LISTS

T0301.EPS

Transmitter

Display

HART output

Monitoring

Mainenance

Item

UHI

Description

Remarks

Tag

Descriptor

Message

Date

Unit

LRV
URV

Apply values

Damp

Xfer fnctn

Low cut

Cut mode

Bi-dire mode

H

2

O Unit select

Snsr temp unit

AO lower limit %
AO upper limit %

Auto recover

Static pres unit

Display mode

Display fnctn

Engr unit

Engr disp LRV

Engr disp URV

Engr disp point

Poll addr

Auto poll

Burst option

Burst mode

Pres
% rnge
A01 out
Snsr temp
Static pres
Engr display

Loop test

Self test

Status

A01 Alarm typ

Write Protect

Enable Write

New password

Ext SW mode

Software seal

Tag number

Descriptor

Message

Date

Unit

Lower range value
Lower range value

Apply values

Damping time constant

Transfer function

Low cut

Cut mode

Bi-directional mode

H

2

O Unit select

Sensor temperature unit

Analog output upper and lower
limits

Auto recover mode

Static pressure unit

Display mode

Display fnctn

Engineering unit

Engineering display LRV

Engineering display URV

Engineering display decimal point

Polling address

Auto poll

Burst mode option

Burst mode

Pressure variable
% output variable
4 to 20 mA output variable
Sensor temperature
Static pressure
Output (in Engr unit)

Test output % setting

Self test

Status

Status of analog output alarm

Write Protect

Enable Write

New password

Ext SW mode

Software seal

Tag number, Up to 8 characters

Up to 16 characters

Up to 32 characters

xx/yy/zz

inH

2

O, inHg, ftH

2

O, mmH

2

O, mmHg, psi, bar, mbar, g/cm

2

,

kg/cm

2

, Pa, kPa, MPa, torr, atm

Set the calibration range by the keypad

Range for 4 to 20 mA DC signal is set with actual input applied.

0.2, 0.5, 1, 1.5, 2, 4, 6, 8, 16, 32 sec

linear/Square root

0 to 20 %

Linear/Zero

On/Off

@4

°

C/@20

°

C (68

°

F)

°

C/

°

F

–5.0% to 110.0%

ON/OFF

inH

2

O, inHg, ftH

2

O, mmH

2

O, mmHg, psi, bar, mbar, g/cm

2

,

kg/cm

2

, Pa, kPa, torr, atm

Normal % , User set , User set & % , Inp pres , Pres & %

linear/Square root

Up to 8 characters

–19999 to 19999

–19999 to 19999

0, 1, 2, 3

1 to 15

No/Yes

Pres , % rnge , A01 out

ON/OFF

–3.2 mA to 21.6 mA
–5.0% to 110.0%

–19999 to 19999

–5.0% to 110.0%

Check using the self-test command.

Display of the result of self-test, calibration of transmitter.

High/Low

Yes/No

8 characters

8 characters

Enable/Inhibit

Keep/Break