7 low voltage directive, 7 low, Voltage – Yokogawa EJA115 User Manual

Page 16: Directive, Caution

Advertising
background image

<2. Handling Cautions>

14

IM 01C22A01-01E

(2) Technical Data

• Models without /PE3

Article 3, Paragraph 3 of PED, denoted as Sound
Engineering Practice (SEP) .

• Models with /PE3

Module: H
Type of Equipment: Pressure Accessory - Vessel
Type of Fluid: Liquid and Gas
Group of Fluid: 1 and 2

Model

PS*

1

(bar)

V(L)

PS-V

(bar-L)

Category*

2

EJA110A

160

0.01

1.6

Article 3,
paragraph 3 (SEP)

EJA120A

0.5

0.01

0.005

Article 3,
paragraph 3 (SEP)

EJA130A

420

0.01

4.2

Article 3,
paragraph 3 (SEP)

EJA130A
With code /PE3

420

0.01

4.2

III

EJA310A

160

0.01

1.6

Article 3,
paragraph 3 (SEP)

EJA430A

160

0.01

1.6

Article 3,
paragraph 3 (SEP)

EJA440A

500

0.01

50

Article 3,
paragraph 3 (SEP)

EJA440A
With code /PE3

500

0.01

50

III

EJA510A

500

0.01

50

Article 3,
paragraph 3 (SEP)

EJA510A
With code /PE3

500

0.01

50

III

EJA530A

500

0.01

50

Article 3,
paragraph 3 (SEP)

EJA530A
With code /PE3

500

0.01

50

III

*1:

PS is maximum allowable pressure for vessel itself.

*2:

Referred to Table 1 covered by ANNEX II of EC Directive
on Pressure Equipment Directive 97/23/EC.

(3) Operation

CAUTION

• The temperature and pressure of fl uid should be

applied under the normal operating condition.

• The ambient temperature should be applied under

the normal operating condition.

• Please pay attention to prevent the excessive

pressure like water hammer, etc. When water
hammer is to be occurred, please take measures
to prevent the pressure from exceeding PS by
setting the safety valve, etc. at the system and the
like.

• When

external

fi

re is to be occurred, please take

safety measures at the device or system not to
infl uence the transmitters.

2.7 Low

Voltage

Directive

Applicable standard : EN61010-1

(1) Pollution Degree 2

"Pollution degree" describes the degree to which

a solid, liquid, or gas which deteriorates dielectric
strength or surface resistivity is adhering. " 2 " applies
to normal indoor atmosphere. Normally, only non-
conductive pollution occurs. Occasionally, however,
temporary conductivity caused by condensation must
be expected.

(2) Installation Category I

"Overvoltage category(Installation category)"

describes a number which defi nes a transient
overvoltage condition. It implies the regulation for
impulse withstand voltage. " I " applies to electrical
equipment which is supplied from the circuit when
appropriate transient overvoltage control means
(interfaces) are provided.

Advertising
This manual is related to the following products: