IM 01C22T02-01E

8-3

8. GENERAL SPECIFICATIONS

Item

Description

Code

CSA Explosionproof Approval *

5

Certificate: 1010820

Explosionproof for Class I, Division 1, Groups B, C and D

Dustignitionproof for Class II/III, Division 1, Groups E, F and G

Temp. Class: T4, T5, T6 Encl Type 4x Amb. Temp.: –40 to 80

°

C (–40 to 176

°

F)

Max. Process Temp.: T4; 120

°

C (248

°

F), T5; 100

°

C (212

°

F), T6; 85

°

C (185

°

F)

Electrical connection: 1/2 NPT female

*1

Process Sealing Certification
Dual seal certified by CSA to the requirement of ANSI/ISA 12.27.01
No additional sealing required. Primary seal failure annunciation : at the zero adjust-
ment screw

CF15

JF35

Canadian Standards
Association (CSA)

T0804.EPS

TIIS Certification

TIIS Flameproof Approval, Ex do II C T4X *

2

*

3

*

5

*

6

PID/LM function

PID control function, Link Master function *

4

LC1

Software download function*

7

Based on F

OUNDATION

Fieldbus Specification (FF-883)

Download class: Class1

EE

*1: Applicable for Electrical connection code 2 and 7.
*2: If cable wiring is to be used, add the YOKOGAWA-assured flameproof packing adapter.
*3: In case the ambient temperature exceeds 45

°

C, use heat-resistant cables with maximum allowable temperature of 75

°

C or above.

*4: Set as basic device when shipped.
*5: See certificate list of TIIS flameproof approval below.

T0805.EPS

With integral indicator

Without integral indicator

Wetted parts material code

S

H, A

T, D

M, B

C15296

C15298

C15300

C15302

C15297

C15299

C15301

C15303

*6: TIIS (The Technology Institution of Industrial Safety) Certification is a new notation for the explosionproof approval in

Japan instead of JIS.

*7: Not applicable for Option code FS15 and KS25.