2-1

2. HANDLING CAUTION

2.

HANDLING CAUTION

2.1 Installation of an Explosion-

Protected Instrument

If a customer makes a repair or modification to an
intrinsically safe or explosionproof instrument and the
instrument is not restored to its original condition, its
intrinsically safe or explosionproof construction may
be compromised and the instrument may be hazardous
to operate. Please contact Yokogawa before making
any repair or modification to an instrument.

CAUTION

This instrument has been tested and certified as
being intrinsically safe or explosionproof. Please
note that severe restrictions apply to this
instrument’s construction, installation, external
wiring, maintenance and repair. A failure to
abide by these restrictions could make the
instrument a hazard to operate.

WARNING

Maintaining the safety of explosionproof equip-
ment requires great care during mounting,
wiring, and piping. Safety requirements also
place restrictions on maintenance and repair.
Please read the following sections very carefully.

WARNING

The range setting switch must not be used in a
hazardous area.

2.1.1 FM approval

a. FM Explosionproof Type

Caution for FM Explosionproof type

Note 1. EJA Series differential, gauge, and absolute

pressure transmitters with optional code /FF15
are applicable for use in hazardous locations:
• Applicable standard: FM3600, FM3615,

FM3810, ANSI/NEMA250

• Explosionproof for Class I, Division 1,

Groups B, C and D.

• Dust-ignitionproof for Class II/III, Division

1, Groups E, F and G.

• Outdoor hazardous locations, NEMA 4X.
• Temperature Class: T6
• Ambient Temperature: –40 to 60

°

C

• Supply Voltage: 32V dc max.
• Current Draw: 16.5 mA dc

Note 2. Wiring

• All wiring shall comply with National

Electrical Code ANSI/NEPA70 and Local
Electrical Codes.

• When installed in Division 1, “FACTORY

SEALED, CONDUIT SEAL NOT RE-
QUIRED.”

Note 3. Operation

• Keep strictly the “CAUTION” on the

nameplate attached on the transmitter.
CAUTION: OPEN CIRCUIT BEFORE

REMOVING COVER.
“FACTORY SEALED, CONDUIT
SEAL NOT REQUIRED.”
INSTALL IN ACCORDANCE
WITH THE INSTRUCTION
MANUAL IM 1C22.

• Take care not to generate mechanical

sparking when accessing the instrument and
peripheral devices in a hazardous location.

Note 4. Maintenance and Repair

• The instrument modification or parts

replacement by other than authorized
representative of Yokogawa Electric Corpo-
ration is prohibited and will void Factory
Mutual Explosionproof Approval.