<A1. Header>

6

IM 01C25R51-10E

6. Information Provision Web Site

For FieldMate and/or PRM users, the user’s web site has been already in operation as follows:

https://voc.yokogawa.co.jp/PMK/Top.do

The FlowNavigator category within the above web site provides the latest software operation environment supporting

information such as documents and update programs.
After registration as a FieldMate user, you can find the “Download” → “FlowNavigator” menu by clicking the information icon on

the top menu. Entering your FSA120 license number allows you to access the information menu for “FlowNavigator”.

Appendix A Flow Parameters Download Procedure

The basic procedure for downloading the flow parameters to a device is as follows. Refer to Figure A-1, A-2.

Step1

Upload from Device

Perform “Upload from Device” so that the setting parameters (“Device Flow Parameters” and “Device General Parameters”) in

the device are saved to the offline database on your PC.
The parameters will then be displayed in the Offline Parameter screen.

Step2

Flow Configuration

Perform Flow configuration in accordance with the guidance in the Flow Configuration Wizard. “Device Flow Parameters” are

output by Flow Configuration Wizard.
Save “Device Flow Parameters” as XMV file (EJXMVTool) or VMV file (DYFMVTool) in the last menu, and click the “Apply”

button.
“Device Flow Parameters” are then stored to the offline database on your PC.

NOTE

Clicking on Apply does not download the flow parameters to the device.

Step3

Download to Device

Perform “Download to Device”. “Device Flow Parameters” will then be downloaded together with the “Device General

Parameters” to the device.