1.3 Login Function

• When Not Using the Multi Login Function

Users cannot log in at the same time through key operations, an Ethernet connection (to

the setting function), or serial communication. Only one user can log in to the DX at a
time.

DX Access Method

When Another User Is Logged In

Key operations

None of the keys function.

Communication (Ethernet

connection to the setting

function)

You cannot log in or send commands.

Communication (serial)

You cannot log in or execute commands that you need to be

logged in to perform. You can execute monitoring-function

commands.

When Not Using Communication Login Function

The communication commands that you can perform are listed below.
• Ethernet communication
You can connect to the setting and measurement server under the name “user.” You

can only use the monitoring-function commands.

• Serial communication
You cannot use the LL command. You can only use the monitoring-function

commands.

How the DX Operates When the Login Function Is Not Used

When the login function is not used (no administrators are registered):
• You do not need to log in. The DX switches to operation mode when you turn on the

power or exit basic setting mode.

• You cannot use the signature function.
• You connect over the Ethernet to the setting and measurement server and execute

commands in the same way as on a standard model.

• You execute serial commands in the same way as on a standard model.