3 error messages and corrective actions, Errors that occur during authentication, Errors that occur during communication – Yokogawa Removable Chassis DX1000N User Manual

Page 67: 3 error messages and corrective actions -4

Advertising
background image

3-4

IM 04L41B01-05EN

3.3 Error Messages and Corrective Actions

Errors That Occur during Authentication

Code

Message

Explanation/Corrective Action

E006

Incorrect input character string.

Check that the host principal, authentication key

password, and realm name settings on the DX are

correct.

E085

The login password is incorrect.

Enter the correct password.

E110

This user name is not registered.

The specified user is not registered on the DX. The user

account is not registered on the server.

E114

This user name is invalid.

The account has been invalidated on the server.
The account has been invalidated on the DX.

E117

This password is not effective.

On the DX, because the wrong password has been

entered consecutively for more than the permissible

number of times, this user is invalid.

E764

Not supported by this machine.

Not supported by the DX.

E765

Preauthentication failed.

Enter the correct password. Also, make sure that the

times on the DX and the server match.

E766

The encryption type is not supported by this machine.

The DX does not support the encryption type, or the

encryption type settings on the DX and the server are

different. Use the same encryption method on the DX and

the server.

E767

Failed to receive authentication from KDC server.

Check the DX and server settings. Also, make sure that

the times on the DX and the server match.

E768

Change the password.

The password has expired. Change the password of the

user account that is registered on the server.

E769

The time difference with the KDC server exceeds the

limit.

There is a time difference of 5 minutes or more between

the DX and the server. Set the DX time to match the time

on the server.

E771

The host principal is not registered.

The host account is not registered on the server.

E772

The host principal is invalid

Check the host account that is registered on the server.

E773

The host password is incorrect.

Make sure that the DX authentication-key password and

the server's host-account password match.

E774

Preauthentication failed.

An internal error occurred during preauthentication.

Disable the server's preauthentication function.

E775

The realm is incorrect.

Make sure that the realm name setting on the DX is

correct.

Errors That Occur during Communication

Code

Message

Explanation/Corrective Action

E260

IP address is not set or ethernet function is not

available.

The server address has not been specified.The Ethernet

is not functioning.

E266

Ethernet cable is not connected.

Make sure that an Ethernet cable is connected.

E760

Cannot find KDC server.

The KDC server cannot be found in the same domain.

E761

KDC server connection error.

An error occurred while the DX was connecting to the

KDC server. Make sure that the network connection is not

broken.