Data D

splay Methods

Zone (dsplay poston)

The input range is as shown below.
• Minimum value: 0 to 99 %
• Maximum value: 1 to 100 %
The waveform display position is set with the lower edge of the waveform display area
of the waveform display screen as 0 % and the upper edge as 100 %. When the zone
display area is clicked, numerical input becomes possible.
When the Y-axis mode setting is “Y-axis free mode”, display is made with the set zone.

Trp lnes

Four settings (trip 1 – red/trip 2 – blue/trip 3 – violet/trip 4 – orange) are possible for each
waveform. Only the trip lines of active waveforms are displayed on the waveform screen.
On the waveform display screen, the display position of trip lines can be changed
by dragging. When the trip line value display area on the “Detail settings” screen of
waveform display is clicked, numerical input becomes possible.

Dsplay messages

Messages to be displayed can be set. Clicking displays the “Display message group”
screen. The display

group to be regstered to the recorder is displayed on this screen.

Check a group to be displayed.

Dsplay color

The color of each waveform can be displayed. Clicking displays the “Set color” screen.
To set any color, click the

[Defne Custom Colors] button of the “Color” dialog box.