Operations on the CX1000/CX2000

With the functional changes, the operations on the CX1000/CX2000 change as follows:

Event Output Setting in Basic Control Settings (New Operation)

Select Common or Separate by carrying out the procedure described below.

•

Common (factory default setting)

Set a common event output setting for all program patterns.

•

Separate

Set the event output for each program pattern.

Displaying the Setting Display

On the CX2000

Press the keys in the following sequence:

MENU key

(switch to the setting mode (control)) >

Hold down the FUNC key for 3

seconds

(switch to the basic setting mode) > #10 soft key (select [Control]) >

#2

soft key

(select [DI/DO/SW-registration, AUX (Alarm mode...)])

From the operation display, use the above keys to open the following setting display.

On the CX1000

Press the keys in the following sequence:

MENU key

(switch to the setting mode (control)) >

Hold down the FUNC key for 3

seconds

(switch to the basic setting mode) >

#12 soft key

(select [Control]) >

#4

soft key

(select [AUX (Alarm mode...)])

From the operation display, use the above keys to open the following setting display.