Yokogawa Standalone MW100 User Manual

Page 31

Advertising
background image

31

4. Appendix

4.1.

Bit timing table


Detailed set selecting items possible range in each Bit rate.

The abbreviation in the table shows the following meaning.

BRP

Baud Rate Prescaler

TQC

Time Quanta Count

SS

Synchronization Segment

SJW

Re-Synchronization Jump Width

BSP

Bit Sample Point


Bit Rate = 10K

Bit Timing

BRP

TQC

SS

TSEG1

TSEG2

SJW

BSP

48 25 1 16 8 1,2,3,4 1

15 8 1,2,3,4

1

50 24 1

16 7 1,2,3,4

1

11 8 1,2,3,4

1

12 7 1,2,3,4

1

13 6 1,2,3,4

1

14 5 1,2,3,4

1

15 4 1,2,3,4

1

60 20 1

16 3 1,2,3

1

8 7 1,2,3,4

1

9 6 1,2,3,4

1

10 5 1,2,3,4

1

11 4 1,2,3,4

1

12 3 1,2,3

1

75 16 1

13 2 1,2 1

8 6 1,2,3,4

1

9 5 1,2,3,4

1

10 4 1,2,3,4

1

11 3 1,2,3

1

80 15 1

12 2 1,2 1

6 5 1,2,3,4

1

7 4 1,2,3,4

1

8 3 1,2,3

1

100 12 1

9 2 1,2

1

5 4 1,2,3,4

1

6 3 1,2,3

1

120 10 1

7 2 1,2

1

4 3 1,2,3

1

150 8 1

5 2 1,2

1

Advertising