Contents displayed on the 7-segment led – Yokogawa PC-Based MX100 User Manual

Page 12

Advertising
background image

12

IM MX100-72E

Contents Displayed on the 7-Segment LED

7-segment LED

DATA ACQUISITION UNIT

ETHERNET

POWER

10BASE - T

100BASE - TX

SW

ON

1 2 3 4 5 6 7 8

The main module has a two-digit
7-segment LED. The 7-segment
LED displays the unit number,
operating status, operation
complete, and operation error of
the MX100/MW100 Data
Acquisition Unit

• Unit Number Display

When connected using the MX100 standard software:

Fixed at

When connected using MXLOGGER software (MX100 only):

-

When connected using the MW100 browser software:

-

• Display of the Self-Test Operation at Power on

When the power is turned ON, the LED displays startup
indications (such as

), and a self-test is carried out. While

the self-test is in progress, the following displays are
repeated.

• Display While Processing Is in Progress

The displays shown below repeats when there is access to
the CF card, when the CF card is being formatted, or when
calibration is taking place.

• Unit Confirmation Display

The figure below shows the display that appears when you
confirm the MX100 Data Acquisition Unit that is connected
using the MX100 Standard Software, MXLOGGER (software
sold separately), or MW IP Config Software. The word “--
CALL--” flows through the display from right to left.

For details on the display and meaning of operation errors,
see section 3.1, “Error Display on the 7-Segment LED and
Corrective Actions” in the MX100 Data Acquisition Unit
User’s Manual or section 4.1, “Error Display on the 7-
Segment LED and Corrective Actions” in the MW100 Data
Acquisition Unit User’s Manual.

• Operation Mode Hold Function Display (Only When

the MX100 /DS Option Function Is Enabled)

Following the self-check, the /DS option function execution
confirmation “

” is displayed.

• Operation Mode Display (MX100 Only)

The MX100 Data Acquisition Unit has three operation modes:
idle mode, measurement mode, and backup mode (measured
data saved to a CF card due to the disconnection of
communications). The modes are displayed as shown below. In
the figure below,

indicates the unit number. If the unit

number is not 00, the specified unit number is displayed.

• Idle mode

• Measurement mode

• Backup mode

Two zeroes

Two zeroes and a dot

Two zeroes and
two dots

• Display When Operation Is Complete (MX100 Only)

The figure below shows the display that appears when an
operation such as IP address configuration, time setup, and
measurement condition change is completed. In the figure
below,

indicates the unit number. If the unit number is not 00,

the specified unit number is displayed.

Turns off for 1 s

• Key Lock Status (MW100 Only)

A key lock function is included for preventing accidental
manipulation of the MW100 front panel keys. The key lock status
is indicated by a dot at the bottom of the unit number. The
example shown is for a unit of number 00.

• Key lock released

• Key lock

Unit Number

Unit number and dot

• Access Forewarning to the CF Card (MW100 Only)

When saving measured, computed, or thinned data, the dots
blink before accessing of the CF card. This indication starts 10
seconds before the access. If you see this indication, quickly
finish the insertion or removal of the CF card.

In-progress display

Blinking

If you are using the multi interval function, this indication may be
shorter than 10 seconds. If the time until the CF card is accessed
is less than or equal to 5 seconds, the time unit access is
displayed numerically.

In-progress display

When performing a manual sample, and when saving report
data, the dots do not blink before accessing of the CF card.

Advertising
This manual is related to the following products: