BEFORE USING THE TX200

Check for any shipping damage. Place a claim with carrier if damage is discovered.

DO NOT USE A DAMAGED UNIT.

Complete and return the Warranty Card within 90 days to activate technical support and warranty
coverage.

Warranty claims can not be honored unless this warranty card is on file within 90 days of
purchase.

The TX200 should not be operated or serviced by any person who has not read all the contents of
this manual. Failure to read and comply with these instructions or any one of the limitations noted
herein can result in serious injury and/or property damage.

These general instructions deal with the normal operation and maintenance situations encountered
with the TX200. The instructions should not be interpreted to anticipate every possible contingency.

It is the responsibility of the technician to operate the TX200 in accordance with all specifications and
laws which may apply.

A few minutes spent reading these instructions can make an operator aware of dangerous practices
to avoid and precautions to take for his own safety and the safety of others.

A regular schedule of inspection of the TX200 should be established and records maintained with
special attention given to valves and hoses.

SAFETY PRECAUTIONS

!

The TX200 is designed to recover most common refrigerants, including, but not limited to R12,
R22, R134a and R502. Do not use the TX200 to recover high pressure refrigerants which have
working pressures above 400 PSIG (27 Bar) at 120

0

F (49

0

C).

!

Wear safety glasses and protective gloves. Refrigerant has a very low boiling point and can
cause frostbite.

!

Follow the TX200 operating procedures sequentially to avoid prematurely disconnecting hoses
or opening valves which may release refrigerant to the atmosphere.

!

Do not expose the TX200 to moisture or operate in wet areas.

!

Use the TX200 in locations with mechanical ventilation that provides at least four air changes per
hour.

!

Hoses used with the TX200 must have shutoff devices within 12 inches (30 cm) of the connection
point to the cooling system being serviced to minimize the release of refrigerant when being
disconnected.

!

Disconnect power before performing any maintenance or service on the TX200.

!

Avoid using an extension cord with the TX200. If necessary, use a good condition, 3-wire
grounded, 14 AWG (2.5 mm

2

) extension cord of the shortest possible length.

!

Connect the TX200 to a properly protected, grounded receptacle. Do not over load the circuit.