Recover – MAHLE RTI TX200 User Manual

Page 4

Advertising
background image

Page 3

RECOVER

1. Various Sizes

Cylinder with OFP Switch

7. 026-80007-00 Sight Glass

2. 025-80115-00

OFP Cord

8. 360-80223-00 Yellow Hose - 8 ft (2.4 m)

3. 360-80223-00

Yellow Hose - 8 ft (2.4 m)

9. 360-80197-00 Blue Hose - 6 ft (1.8 m)

4. 360-80226-02

Yellow Hose - 2 ft (0.6 m)

10. 360-80196-00 Red Hose - 6 ft (1.8 m)

5. 026-80089-00

Filter

11. 026-80200-00 Gauge Manifold

6. 023-80004-01

Connector 1/4 FFL-1/4 FFL

Close all valves and turn TX200 valve to OFF.

Connect the TX200, filter, sight glass and gauge manifold as shown.

Connect red and blue hoses from gauge manifold to the appropriate ports on the cooling system to
be recovered.

Connect Hose 3 to the liquid port of Cylinder 1. Do not rely on the colors of the valve knobs to indicate
liquid or vapor. Check the embossed printing on the knobs.

Cylinder 1 must have an Overfill Protection (OFP) level switch. Disconnect TX200 from power source
while connecting the OFP cord to the level switch. Do not force the plug into the OFP level switch.
Look at the pins in the plug and align them with sockets in the OFP level switch.

Connect TX200 Power Cord to a properly protected, grounded receptacle. Avoid using an extension
cord with the TX200. If necessary, use a good condition, 3-wire grounded, 14 AWG (2.5 mm

2

)

extension cord of the shortest possible length.

The TX200 is now ready to recover refrigerant.