COMPRESSOR MAINTENANCE

Check the TX200 Compressor oil level before each recovery procedure. The Oil Level Sight Tube is
visible through a cut-out on the side of the unit.

The level should be maintained within the lower one half inch of the tube.

TO ADD COMPRESSOR OIL

Run the TX200 with the Inlet Hose Ball Valve closed until the Compressor On Light goes Off. Press
and hold the Deep Vacuum Switch for approximately 30 seconds to draw a deeper vacuum. Leave
the TX200 power on. Pour 3GS Compressor Oil into the measuring cup. Insert the end of the Inlet
Hose into the Oil and slightly open the Ball Valve. Oil will be drawn into the TX200 due to the vacuum
in the hose. Draw approximately 30 ml of Oil into the TX200 and close the valve. Use the TX200 for
a recovery job and again check the oil level.

CONDENSER MAINTENANCE

Clean the Condenser to maintain high efficiency performance of the TX200. Disconnect power and
remove the Cover. Blow compressed air through the cooling fins of the Condenser to remove any
debris. Replace the Cover before applying power to the TX200.

FILTER REPLACEMENT

Replace the Filter according to the following:

After every Job Involving a Compressor Burn-out

After every 20 Jobs Involving Normal Service